HUBUNGAN JUMLAH ANGKA LEMPENG TOTAL DENGAN JUMLAH ANGKA ENDOTOKSIN PADA AIR REVERSE OSMOSIS HEMODIALISA

Rita Yuliati, Misbahul Subhi, Ike Dian Wahyuni

Abstract


Reverse Osmosis water is a major component in the hemodialysis process, acting as a solvent for dialysate fluid. The microbiological quality of Reverse Osmosis water significantly impacts patient safety, particularly with regard to endotoxin contamination originating from the cell walls of Gram-negative bacteria. This 2025 study aimed to analyze the relationship between total plate count (ALT) and endotoxin levels in Reverse Osmosis water in the hemodialysis unit of Hospital X, Mojokerto City. This study used an analytical observational design with a cross-sectional approach. Samples were obtained from a single location, namely water produced by the Reverse Osmosis machine that was ready to be flowed into the hemodialysis machine. Sampling was carried out 20 times, 10 samples of Total Plate Count and 10 samples of Endotoxin for five consecutive days at two different times each day, namely the morning shift (around 08.00–10.00) and the afternoon shift (around 13.00–15.00). ALT was examined using the pour plate method, and endotoxin levels were measured with the Nexgen device using the chromogenic LAL method. Based on the Spearman test results, a correlation coefficient (r) value of -0.518 was obtained with a significance value (p) of 0.125 (p > 0.05), which indicates that there is a moderate negative relationship between ALT and endotoxin levels, but this relationship is not statistically significant at the 95% confidence level (α = 0.05). Therefore, in this study, changes in the Total Plate Count (ALT) did not affect the amount of endotoxin.

 


Keywords


reverse osmosis, total plate count, endotoxin, hemodialysis, microbiological quality

Full Text:

PDF

References


Azeredo, J., Azevedo, N. F., Briandet, R., Cerca, N., Coenye, T., Costa, A. R., ... & Oliveira, R. (2017). Critical review on biofilm methods. Critical Reviews in Microbiology, 43(3), 313–351. https://doi.org/10.3109/1040841X.2015.1114465

Cahyadi, I., Susilo, Y., & Nurhayati, N. (2016). Kajian kualitas air Reverse Osmosis (RO) pada unit hemodialisa rumah sakit. Jurnal Kesehatan Lingkungan Indonesia, 15(2), 71–78.

Gulati, M., & Ghosh, M. (2017). Endotoxin contamination in dialysis water and its clinical implications. Indian Journal of Nephrology, 27(2), 121–126.

ISO. (2019). ISO 23500-3: Preparation and quality management of fluids for haemodialysis and related therapies – Part 3: Water for haemodialysis and related therapies. International Organization for Standardization.

Kementerian Kesehatan Republik Indonesia. (2023). Peraturan Menteri Kesehatan Republik Indonesia Nomor 129 Tahun 2023 tentang Standar Pelayanan Hemodialisa. Jakarta: Kemenkes RI.

Notoatmodjo, S. (2012). Metodologi penelitian kesehatan. Jakarta: Rineka Cipta.

Riskesdas. (2018). Laporan Nasional Riset Kesehatan Dasar 2018. Badan Penelitian dan Pengembangan Kesehatan, Kementerian Kesehatan RI.

Global Burden of Disease. (2019). GBD Compare Data Visualization. Institute for Health Metrics and Evaluation (IHME). Retrieved from https://vizhub.healthdata.org/gbd-compare/

Setyono, D., & Wahyuni, I. (2019). Uji mikrobiologi terhadap air hasil Reverse Osmosis di rumah sakit menggunakan metode ALT. Jurnal Laboratorium Medik, 5(1), 35–41.




DOI: http://dx.doi.org/10.35329/jkesmas.v11i2.6546

Article Metrics

Abstract views : 12 times | PDF - 0 times


Alamat Penyunting & Distribusi:

Kantor LPPM Universitas Al Asyariah Mandar  Gedung Rektorat Lt 1. Jl. Budi Utomo No.2 Manding. Kec. Polewali, Kab. Polewali Mandar, Prov. Sulawesi Barat

Email: jkesmanfkm@gmail.com

Website: https://journal.lppm-unasman.ac.id/index.php/jikm/index

Penerbit:
Lembaga Penelitian dan Pengabdian Masyarakat Universitas Al Asyariah Mandar


Indexed by:

           

   

Member of:

 

 

Creative Commons License
J-Kesmas is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.


situs t

 

https://ihdn.ac.id/